Clarion ProSecurity RK20 Guida di Installazione Pagina 43

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 60
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 42
© 2007 Directed Electronics—all rights reserved 43
FEATURE NUMBER ONE-CHIRP SETTING (DEFAULT) TWO-CHIRP SETTING
2-1 30 second siren duration* 60 second siren duration*
2-2 Nuisance Prevention Circuitry ON Nuisance Prevention Circuitry OFF
2-3 Progressive door trigger Instant door trigger
2-4 Disarm from Valet, 1 pulse Disarm from Valet, 2-5 pulses
2-5 Door sensor bypass chirp ON Door sensor bypass chirp OFF
2-6 Ignition controlled domelight ON Ignition controlled domelight OFF
2-7 Unlock output 1 pulse Unlock output 2 pulses
2-8 Lock output 1 pulse Lock output 2 pulses
2-9 Factory disarm with Channel Two ON Factory disarm with Channel Two OFF
2-10 FAD function with Unlock (1) Before Unlock (2), Remote Start only (3)
2-11 FAD 1 pulse 2 pulses
2-12 Channel 4 validity (1) Latched (2), Latch reset with ignition
(3), 30-sec. timed (4)
2-13 Channel 4 linking None (1) Arm (2), Disarm (3), Remote Start (4)
2-14 Channel 5 validity (1) Latched (2), Latch reset with ignition
(3), 30-sec. timed (4)
2-15 Channel 5 linking None (1) Arm (2), Disarm (3), Remote Start (4)
2-16 Channel 6 validity (1) Latched (2), Latch reset with ignition
(3), 30-sec. timed (4)
2-17 Channel 6 linking None (1) Arm (2), Disarm (3), Remote Start (4)
*NOTE: The Prosecurity programmer can set 1-180 seconds.